Home | Profile | Quality | Technical Info | Products | Standard Assemblies | Laboratory Glassware | Glass Jacketed Vessels | Glass Tubes | PTFE Lined Products | PTFE Labware | Plastic Labware | Contact Us |Feedback | Sitemap
Pipeline
Components |
Valves
& Filters | Heat
Exchangers | Vessels
& Stirrers | Column
Components |
Pumps
| Control
| Couplings
| Structure
| Sight
Glasses
Introduction |
|
Tee Equal Long |
Pipe Sections | Tee Unequal | |
Reducers | Crosses Equal | |
90o Bends | Pipe Closure | |
45o Bends | Hose Connector | |
Tee Equal | 90o Reducing Bends |
Borosilicate
glass pipeline components find universal application throughout the worlds chemical,
pharmaceutical, food and drink and allied industries where the advantage of using glass as
a basis for the construction of complete process systems have long been recognized: The complete range of pipeline components is described on the following pages.
Components with a standard flat buttress ends are available from DN 25 to DN450. |
DN |
DN1 |
L |
Cat Ref |
|
40 |
25 |
100 |
GPR 1.5/1 |
|
50 |
25 |
100 |
GPR 2/1 |
|
50 |
40 |
100 |
GPR 2/1.5 |
|
80 |
25 |
125 |
GPR 3/1 |
|
80 |
40 |
125 |
GPR 3/1.5 |
|
80 |
50 |
125 |
GPR 3/2 |
|
100 |
25 |
150 |
GPR 4/1 |
|
100 |
40 |
150 |
GPR 4/1.5 |
|
100 |
50 |
150 |
GPR 4/2 |
|
100 |
80 |
150 |
GPR 4/3 |
|
150 |
25 |
200 |
GPR 6/1 |
|
150 |
40 |
200 |
GPR 6/1.5 |
|
150 |
50 |
200 |
GPR 6/2 |
|
150 |
80 |
200 |
GPR 6/3 |
|
150 |
100 |
200 |
GPR 6/4 |
|
225 |
25 |
250 |
GPR 9/1 |
|
225 |
40 |
250 |
GPR 9/1.5 |
|
225 |
50 |
250 |
GPR 9/2 |
|
225 |
80 |
250 |
GPR 9/3 |
|
225 |
100 |
250 |
GPR 9/4 |
|
225 |
150 |
250 |
GPR 9/6 |
|
300 |
25 |
275 |
GPR 12/1 |
|
300 |
40 |
275 |
GPR 12/1.5 |
|
300 |
50 |
275 |
GPR 12/2 |
|
300 |
80 |
275 |
GPR 12/3 |
|
300 |
100 |
300 |
GPR 12/4 |
|
300 |
150 |
300 |
GPR 12/6 |
|
300 |
225 |
300 |
GPR 12/9 |
|
450 |
25 |
325 |
GPR 18/1 |
|
450 |
40 |
325 |
GPR 18/1.5 |
|
450 |
50 |
325 |
GPR 18/2 |
|
450 |
80 |
375 |
GPR 18/3 |
|
450 |
100 |
375 |
GPR 18/4 |
|
450 |
150 |
375 |
GPR 18/6 |
|
450 |
225 |
375 |
GPR 18/9 |
|
450 |
300 |
375 |
GPR 18/12 |
DN |
L |
Cat Ref |
|
25 |
100 |
GPB 90/1 |
|
40 |
150 |
GPB 90/1.5 |
|
50 |
150 |
GPB 90/2 |
|
80 |
200 |
GPB 90/3 |
|
100 |
250 |
GPB 90/4 |
|
150 |
250 |
GPB 90/6 |
|
225 |
375 |
GPB 90/9 |
|
300 |
450 |
GPB 90/12 |
|
450 |
600 |
GPB 90/18 |
90° Bends with
Thermometer Branch
DN (mm) |
DN1 (mm) |
L (mm) |
L1 (mm) |
Cat.
Ref. |
|
50 |
25 |
150 |
225 |
GPBT 2 |
|
80 |
25 |
200 |
280 |
GPBT 3 |
|
100 |
25 |
250 |
330 |
GPBT 4 |
|
150 |
25 |
250 |
340 |
GPBT 6 |
|
225 |
25 |
375 |
480 |
GPBT 9 |
These items
allow a thermometer to be incorporated into an installation.
DN |
DN1 |
L |
L1 |
Cat Ref |
|
40 |
25 |
150 |
125 |
GPBR 1.5/1 |
|
50 |
40 |
150 |
150 |
GPBR 2/1.5 |
|
80 |
50 |
150 |
150 |
GPBR 3/2 |
|
100 |
50 |
200 |
150 |
GPBR 4/2 |
|
100 |
80 |
200 |
175 |
GPBR 4/3 |
|
150 |
50 |
200 |
150 |
GPBR 6/2 |
|
150 |
80 |
250 |
175 |
GPBR 6/3 |
|
225 |
80 |
250 |
175 |
GPBR 9/3 |
|
300 |
80 |
300 |
175 |
GPBR 12/3 |
|
300 |
150 |
450 |
250 |
GPBR 12/6 |
|
450 |
150 |
450 |
250 |
GPBR 18/6 |
DN |
L |
Cat Ref |
|
25 |
75 |
GPB 45/1 |
|
40 |
100 |
GPB 45/1.5 |
|
50 |
100 |
GPB 45/2 |
|
80 |
125 |
GPB 45/3 |
|
100 |
175 |
GPB 45/4 |
|
150 |
200 |
GPB 45/6 |
|
225 |
225 |
GPB 45/9 |
|
300 |
275 |
GPB 45/12 |
DN |
L |
Cat Ref |
|
25 |
70 |
GPT 1 |
|
40 |
90 |
GPT 1.5 |
|
50 |
100 |
GPT 2 |
|
80 |
125 |
GPT 3 |
|
100 |
175 |
GPT 4 |
|
150 |
225 |
GPT 6 |
|
225 |
300 |
GPT 9 |
|
300 |
450 |
GPT 12 |
DN |
L |
Cat Ref |
|
25 |
100 |
GPTL 1 |
|
40 |
150 |
GPTL 1.5 |
|
50 |
150 |
GPTL 2 |
|
80 |
200 |
GPTL 3 |
Tee Piece to Interchange with 90° Bend
DN |
DN1 |
L |
L1 |
Cat Ref |
|
40 |
25 |
200 |
75 |
GPTU 1.5/1 |
|
50 |
25 |
200 |
80 |
GPTU 2/1 |
|
50 |
40 |
200 |
100 |
GPTU 2/1.5 |
|
80 |
25 |
250 |
100 |
GPTU 3/1 |
|
80 |
40 |
250 |
100 |
GPTU 3/1.5 |
|
80 |
50 |
250 |
115 |
GPTU 3/2 |
|
100 |
25 |
250 |
110 |
GPTU 4/1 |
|
100 |
40 |
250 |
125 |
GPTU 4/1.5 |
|
100 |
50 |
250 |
125 |
GPTU 4/2 |
|
100 |
80 |
300 |
150 |
GPTU 4/3 |
|
150 |
25 |
250 |
150 |
GPTU 6/1 |
|
150 |
40 |
250 |
150 |
GPTU 6/1.5 |
|
150 |
50 |
250 |
150 |
GPTU 6/2 |
|
150 |
80 |
300 |
175 |
GPTU 6/3 |
|
150 |
100 |
300 |
200 |
GPTU 6/4 |
|
225 |
25 |
300 |
185 |
GPTU 9/1 |
|
225 |
40 |
300 |
185 |
GPTU 9/1.5 |
|
225 |
50 |
300 |
190 |
GPTU 9/2 |
|
225 |
80 |
300 |
210 |
GPTU 9/3 |
|
225 |
100 |
450 |
250 |
GPTU 9/4 |
|
225 |
150 |
450 |
275 |
GPTU 9/6 |
|
300 |
25 |
400 |
230 |
GPTU 12/1 |
|
300 |
40 |
400 |
230 |
GPTU 12/1.5 |
|
300 |
50 |
400 |
230 |
GPTU 12/2 |
|
300 |
80 |
400 |
250 |
GPTU 12/3 |
|
300 |
100 |
400 |
275 |
GPTU 12/4 |
|
300 |
150 |
450 |
300 |
GPTU 12/6 |
|
300 |
225 |
600 |
300 |
GPTU 12/9 |
|
450 |
25 |
400 |
320 |
GPTU 18/1 |
|
450 |
40 |
400 |
320 |
GPTU 18/1.5 |
|
450 |
50 |
400 |
320 |
GPTU 18/2 |
|
450 |
80 |
400 |
320 |
GPTU 18/3 |
|
450 |
100 |
400 |
320 |
GPTU 18/4 |
|
450 |
150 |
600 |
380 |
GPTU 18/6 |
|
450 |
225 |
800 |
400 |
GPTU 18/9 |
|
450 |
300 |
800 |
400 |
GPTU 18/12 |
DN |
L |
Cat Ref |
|
25 |
100 |
GPX 1 |
|
40 |
150 |
GPX 1.5 |
|
50 |
150 |
GPX 2 |
|
80 |
200 |
GPX 3 |
|
100 |
250 |
GPX 4 |
|
150 |
250 |
GPX 6 |
DN |
L |
Cat Ref |
|
25 |
75 |
GPBE 1 |
|
40 |
75 |
GPBE 1.5 |
|
50 |
100 |
GPBE 2 |
|
80 |
95 |
GPBE 3 |
|
100 |
140 |
GPBE 4 |
|
150 |
140 |
GPBE 6 |
|
225 |
155 |
GPBE 9 |
|
300 |
180 |
GPBE 12 |
DN |
d |
L |
Cat Ref |
|
25 |
20 |
90 |
GPHC1/.75 |
|
25 |
26 |
90 |
GPHC1/1 |
|
40 |
26 |
100 |
GPHC1.5/1 |
|
40 |
42 |
100 |
GPHC1.5/1.5 |
Copyrights Reserved 2001-2007 by Garg Scientific Glass Industries. |